Client Configuration
All BlueZone Display emulators need to be configured in order to communicate with the BlueZone License Manager. This is accomplished through the standard BlueZone configuration interface.
Launch your BlueZone emulator or BlueZone Secure FTP Client.
On the BlueZone MenuBar, select Session:Configure. The BlueZone Session Configuration dialog will display.
Select the License Manager tab.
Enter the IP Address of the server that the License Manager is installed on in the Add Server edit box.
NOTE If
you changed your Listening Port from the default of 8421, as shown in
License
Manager Options, you
must add the configured port number to the end of the IP address, using
a coma as a separator.
Example: 63.75.199.234,80
CAUTION! Do
not use a colon ( : ) between
the IP Address and the Port number. You
must use a coma as shown above.
Click the Add button.
Enter a Group name if you are using that option.
Click the OK button.
Your BlueZone emulation client or BlueZone Secure FTP client will now be able to obtain a license from the BlueZone License Manager.
Related Topics:
Loss of Communication with the License Manager