Load Definitions Facility for MySQL
The Load Definitions functionality is supported for MySQL.
Functionality
The Load Definitions facility for MySQL loads tables, views, columns, and indexes. Loading is based on generated columns, also sometimes called computed columns.
It does not load relationships.
Configuration
Before loading definitions from MySQL:
- Specify the MQL connector in the [DRIVERS] section of the IDE assignment file.
- Define the $MQL path in the [PATHS] section of the IDE assignment file.
For more detailed instructions, see Import Data Definitions From a DBMS .
Data Type Mapping
The Load Definitions utility maps MySQL data types to Uniface data types and packing codes. The following table lists these mappings.
MySQL Data Type |
Supported by Load Definitions |
Uniface Data Type |
Uniface Packing Code |
Remarks |
---|---|---|---|---|
bigint |
Yes |
N |
I8 |
Range -9,223,372,036,854,775,808 to 9,223,372,036,854,775,807 |
int | Yes | N | I4 | Range -2,147,483,648 to 2,147,483,647 |
mediumint | Yes | N | l3 | Range -8,388,608 to 8,388,607 |
smallint |
Yes |
N |
I2 |
Range -32,768 to 32,767 |
tinyint | Yes | N | l1 | Range 0 to 255 (negative numbers are not permitted) |
char, character |
Yes |
S |
Cn |
n<=254 |
varchar, long varchar |
Yes |
S |
VCn |
n>=255 |
longtext | Yes | S | SC* | |
binary | Yes | R | Rn | |
varbinary | Yes | R | SRn | |
longblob | Yes | R | SR* | |
date |
Yes |
D |
D |
Uniface does not allow BC dates. |
time |
Yes |
T |
T |
Uniface accuracy is limited to ticks. |
datetime | Yes | E | E | |
decimal(p,s) and numeric(p,s) |
Yes |
N |
N(p+1).s, N(p+1) |
pis precision (total number of digits); for Uniface p must be 30 max, field is skipped with a warning if p is larger. sis scale (number of decimal places); for Uniface s must be smaller than p, field is skipped with a warning if they are equal. s=0 generates N(p+1), rather than N(p+1).0 A ValRep is generated to enforce the exact DBMS max/min values during data entry and store validation. |
float |
Yes |
F |
F4 |
Uniface allows -1e+38 to 1e+38 Uniface will read the full database range. Storing outside the Uniface range generates an error. |
double, double precision |
Yes |
F |
F8 |
Uniface allows -1e+38 to 1e+38 Uniface will read the full database range. Storing outside the Uniface range generates an error. |
Other data types |
The following data types are skipped with a warning message TYPE_NOT_SUPPORTED:
Fields with a data type that is not known in the service are skipped with a warning message: TYPE_NOT_RECOGNIZED. |