Connecting to the Host System


iSeries Display Session Configuration

Prior to establishing an iSeries host system connection, BlueZone users must set Session Configuration parameters.  A Session configuration consists of selecting:

BlueZone can connect to an iSeries host system in one of two ways: Renex Async Protocol, and TN5250/TN5250E. TN5250/TN5250E is by far the most prevalent type of connection. TN5250E supports both display and printer data streams.

From the BlueZone MenuBar, choose Session:Configure.  The Session Configuration dialog will appear.


Connection Tab

Communications Library ----

BlueZone displays the available host connection options. Select the appropriate link for additional configuration information.

NOTE  BlueZone will default to the Connection Type that was chosen during installation.

Renex Async Protocol - Select to connect to the host system using a SEAGULL TMS or RPad Communications Controller.

TN5250/TN5250E - Select to connect to the host system via TCP/IP using the TN5250/TN5250E protocol.

NOTE  The other connection types that appear in this Connection Type list are non-operative.


Options ----

After selecting the Connection Type, select from the following options.

NOTE The Device obtained by the re-connect might not be the same as with the prior session.

NOTE  The Device obtained by the re-connect might not be the same as with the prior session.


5250 Emulation Tab

Translation ----

The Translation group is used to select a translate language and if needed to configure the Translate Tables. Choices include:

NOTE  The language should correspond to the Windows operating system language.

SEE  How to Configure Euro Support for more information.

SEE  How to Edit the Translate Tables for more information.

SEE  How to Configure DBCS Support for more information.


Default Screen Model Type ----

This group is used to configure the IBM Terminal model that you want to emulate. Use the "pull down" menu to display the list of IBM terminals.

IBM-3179-2 (24 x 80 Color)
IBM-3180-2 (27 x 132 Monochrome)
IBM-3196-A1 (24 x 80 Monochrome)
IBM-3477-FC (27 x 132 Color)
IBM-3477-FG (27 x 132 Monochrome)
IBM-5251-11 (24 x 80 Monochrome)
IBM-5291-1 (24 x 80 Monochrome)
IBM-5292-2 (24 x 80 Color)
IBM-5555-B01 (24 x 80 DBCS Monochrome)
IBM-5555-C01 (27 x 132 DBCS Color)
IBM-5555-C01 (27 x 80 DBCS Color)


Keyboard Type Ahead ----

Choose the Type Ahead mode that you require clicking the corresponding radio button.


Options ----

Used to configure 5250 Emulation options.


License Manager Tab

The License Manager Tab is used to store the IP address of the SEAGULL License Manager server.  This is necessary when using a "Concurrent" licensing scheme.

NOTE  The License Manager Tab will only appear if you are using a "Licensed" copy of BlueZone. If you currently "evaluating" BlueZone this tab will not appear.

License Servers ----

Use this group to configure your SEAGULL License Manager IP address.

NOTE  If your SEAGULL License Manager is using a Listening Port other than the default of 8421, you must add the configured port number to the end of the IP address, using a coma as a separator.

Example: 63.75.199.234,80

CAUTION  Do not use a colon (:) between the IP Address and the Port number.  You must use a coma as shown above.


Group Information ----

This field is only used if you are using the Group feature of the SEAGULL License Manager.


Related Topics:

Renex Async Protocol

TN5250E Configuration

Establishing a Host Session